Advertisement

Forensic assessment on the application of a virtual pool of 30 Y-STRs

Published:October 27, 2022DOI:https://doi.org/10.1016/j.fsigss.2022.10.075

      Abstract

      Ideally, a panel of Y short tandem repeats (Y-STRs) should include markers with gene diversity (GD) ≥ 0.70 to guarantee a highly accurate and precise individual identification in all forensic situations where Y loci analysis is necessary to support the findings obtained with autosomal STRs. Since not all markers in a multiplex set reach the optimal GD value, to achieve a greater discrimination capacity (DC), the number of Y-STRs has been gradually expanded also with the addition of rapidly mutating Y-STRs (RM Y-STRs). The present study has tried to assess, based on the genetic diversity of each Y-STR and the cumulative haplotype diversity provided by the single Y-STR panels tested, whether to increase in the number of Y-STRs is effective. For this purpose, three commercially available forensic kits - the PowerPlex® Y23 System, the Yfiler™ Plus PCR Amplification Kit, and the ForenSeq™ DNA Signature Prep Kit - that allow for the simultaneous analysis of 22–25 Y chromosome markers (including Y-STRs and RM Y-STRs) have been used for typing 115 unrelated male individuals from North-East Italy employing two capillary electrophoresis (Applied Biosystems® 3130 Genetic Analyzer and SeqStudio Genetic Analyzer for HID) and one massively parallel sequencing (MiSeq FGx™ Forensic Genomics System) systems. Forensic parameters, such as gene diversity, cumulative haplotype diversity (cHD), and discrimination capacity, were determined for the three Y-STRs kits and the virtual pool of 30 Y-STRs obtained by the overall combination of the Y-loci of the three kits. From the findings, it emerges that twelve markers in the virtual panel of 30 Y-STRs, are characterized by a value of GD ≥ 0.70, and of these, eleven included in the Yfiler™ Plus kit seem to be sufficient to ensure the achievement of haplotype resolution. In light of this, it does not appear necessary to expand the number of Y-STRs in the currently available kits.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Forensic Science International: Genetics Supplement Series
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      Reference

        • Kayser M.
        • Caglià A.
        • Corach D.
        • et al.
        Evaluation of Y-chromosomal STRs: a multicenter study.
        Int. J. Leg. Med. 1997; 110: 125-133