Advertisement
Research article| Volume 1, ISSUE 1, P112-114, August 2008

Development of a novel miniSTR multiplex assay for typing degraded DNA samples

  • Ronny Decorte
    Correspondence
    Corresponding author at: K.U.Leuven, Campus Gasthuisberg O&N1, Herestraat 49 – Bus 602, B-3000 Leuven, Belgium. Tel.: +32 16 345860; fax: +32 16 345997.
    Affiliations
    Laboratory of Forensic Genetics and Molecular Archaeology, Department of Human Genetics – K.U.Leuven, Belgium

    Department of Forensic Medicine – University Hospitals Leuven, Belgium
    Search for articles by this author
  • Chi Fung Liu
    Affiliations
    Laboratory of Forensic Genetics and Molecular Archaeology, Department of Human Genetics – K.U.Leuven, Belgium
    Search for articles by this author
  • Nancy Vanderheyden
    Affiliations
    Laboratory of Forensic Genetics and Molecular Archaeology, Department of Human Genetics – K.U.Leuven, Belgium

    Department of Forensic Medicine – University Hospitals Leuven, Belgium
    Search for articles by this author
  • Jean-Jacques Cassiman
    Affiliations
    Laboratory of Forensic Genetics and Molecular Archaeology, Department of Human Genetics – K.U.Leuven, Belgium

    Department of Forensic Medicine – University Hospitals Leuven, Belgium
    Search for articles by this author

      Abstract

      A multiplex PCR was developed for the analysis of the sex-determining gene Amelogenin, four conventional STR (short tandem repeat; THO1, D18S51, D21S11 and FGA) loci with a reduced amplicon size and four miniSTR loci (D1S1677, D2S441, D10S1248 and D22S1045). A concordance study in a population of 198 Belgians revealed no differences for the conventional STR loci while a sensitivity study showed a reproducible DNA profile with as low as 30 pg of input DNA.

      Keywords

      1. Introduction

      The analysis of DNA samples in forensic casework has until recently relied on the use of commercial multiplex STR (short tandem repeat) systems in a length range of 100–400 base pairs (bp). The application of such systems results in a full DNA profile in the majority of high-quality DNA samples. However, the increased demand to analyze limited DNA samples from evidential skin contact (currently 50% of the workload) or skeletal remains increases the number of samples where only a partial DNA profile is obtained due to low-quantity DNA and/or DNA degradation. It has been demonstrated that the sensitivity for degraded DNA samples can be increased by reducing the size of the STR amplicons (miniSTRs) through relocation of the primers closer to the repeat region [
      • Coble M.D.
      • Butler J.M.
      Characterization of new miniSTR loci to aid analysis of degraded DNA.
      ,
      • Grubweiser P.
      • et al.
      A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA.
      ,
      • Butler J.M.
      • Shen Y.
      • McCord B.R.
      The development of reduced size STR amplicons as tools for the analysis of degraded DNA.
      ].
      The objectives of our study were to develop a miniSTR mutiplex assay that should partially complement the existing commercial multiplex STR systems and at the same time include several miniSTRs that have been recommended as additional loci for the European Standard Set of Loci [
      • Gill P.
      • et al.
      The evolution of DNA databases—recommendations for new European STR loci.
      ,
      • Gill P.
      • et al.
      Letter to the Editor – New multiplexes for Europe – Amendments and clarification of strategic development.
      ].

      2. Materials and methods

      DNA amplification was done in a reaction volume of 25 μl using Qiagen® Multiplex PCR Kit (Qiagen, Hilden, Germany), 5 μl of optimized primer-mix (Table 1; forward primers were fluorescently labelled) and 5 μl of DNA (0.5–1 ng) under standard PCR conditions of 15 min at 95 °C, 30 cycles of 1 min at 94 °C, 1 min at 55 °C and 1 min at 72 °C (“9600” ramp speed), and a final extension of 45 min at 60 °C on a GeneAmp 9700 PCR System (Applied Biosystems, Foster City, CA). PCR products (1 μl) were analyzed on an ABI PRISM 3130 XL Genetic Analyzer (Applied Biosystems) with a 37 cm capillary and using POP-6™ as separation medium. Fragment size determination and genotyping were done with GeneMapper v3.2 (Applied Biosystems) and GS-500[LIZ] as the internal size standard. Allelic ladders were developed for the novel miniSTR loci (D1, D2, D10 and D22) by pooling the amplification products for different alleles from a population study and re-amplification. Allelic ladders for the other loci were obtained by following the procedure described by Coble []. Allele frequencies, match probability and power of exclusion were calculated with PowerStats V1.2 (Promega, Madison, WI).
      Table 1Selected loci included in the miniSTR multiplex assay
      LocusSize range (bp)Match probabilityPower of exclusionFluorescent labelPrimer sequences
      AMEL126–1326-FAM
      D1S166778–117p0.1220.624PET
      • Coble M.D.
      • Butler J.M.
      Characterization of new miniSTR loci to aid analysis of degraded DNA.
      D2S44175–1100.1240.4726-FAM
      • Coble M.D.
      • Butler J.M.
      Characterization of new miniSTR loci to aid analysis of degraded DNA.
      D10S124880–1350.1030.439VIC
      • Coble M.D.
      • Butler J.M.
      Characterization of new miniSTR loci to aid analysis of degraded DNA.
      D18S51110–1900.0350.732NED
      • Grubweiser P.
      • et al.
      A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA.
      D21S11145–2200.0430.672VIC
      • Butler J.M.
      • Shen Y.
      • McCord B.R.
      The development of reduced size STR amplicons as tools for the analysis of degraded DNA.
      D22S104574–1100.1270.532NED
      • Coble M.D.
      • Butler J.M.
      Characterization of new miniSTR loci to aid analysis of degraded DNA.
      THO1145–1900.0910.6926-FAM
      • Kimpton C.P.
      • et al.
      Automated DNA profiling employing multiplex amplification of short tandem repeat loci.
      FGA118–2700.0380.773PET
      • Grubweiser P.
      • et al.
      A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA.
      Combined1.03 × 10−90.99968
      Match probability and power of exclusion were calculated from the data of a population study of 198 Caucasians of Belgian descent.

      3. Results and discussion

      The following criteria were used for the selection of STR loci for the miniSTR mutiplex: inclusion of miniSTR loci recommended as novel loci for the European Standard Set of Loci (Table 1; D2, D10 and D22); observed locus dropout of at least 40% in casework samples with partial profiles and a matching probability of less than 0.05; included in the European Standard Set of Loci (Table 1; D21, D18 and FGA). In addition, AMEL and THO1 were also included while D1S1677 was selected for its size less than 120 bp. The primers were chosen from literature so that the length of the amplicons was less than 200 bp for the most frequent observed alleles.
      The optimized PCR protocol was applied to a DNA panel of 198 Belgian Caucasians previously typed with PowerPlex® 16 [
      • Decorte R.
      • et al.
      Allele frequency data for 19 short tandem repeats (PowerPlex® 16 and FFFl) in a Belgian population sample.
      ]. Full concordance was found for the common loci THO1, D18S51, D21S11 and FGA indicating that the redesigned primer sets do not lead to allele dropout or size shifts due to the presence of a primer-binding site mutation or an insertion/deletion in the flanking site [
      • Vanderheyden N.
      • et al.
      Identifcation and sequence analysis of discorcant phenotypes between AmpFlSTR SGM Plus™ and PowerPlex® 16.
      ,
      • De Maesschalck K.
      • et al.
      Y-chromosomal STR haplotypes in a Belgian population sample and identification of a micro-variant with a flanking site mutation at DYS19.
      ]. Different alleles for D1, D2, D10 and D22 were selected from the population study and sequenced in order to identify the number of repeats. These selected alleles were then used for the construction of allelic ladders for the miniSTR loci. No deviation from Hardy–Weinberg equilibrium was observed. The combined match probability and power of exclusion shows the discriminatory value of this novel multiplex in forensic casework and paternity determinations.
      A sensitivity study on a serial dilution of DNA samples under the standard conditions of 30 cycles showed the occurrence of allele dropout or locus dropout when the DNA input was less than 100 pg of DNA. By increasing the number of cycles to 34, a reproducible DNA profile was obtained when the amount of DNA was decreased to 30 pg of DNA (Fig. 1). This sensitivity was two- to four-fold higher in comparison to the commercial STR multiplexes (e.g. SGM Plus or PowerPlex® 16). The forensic usefulness was demonstrated in an identification case of skeletal remains that showed DNA degradation. Application of the developed miniSTR multiplex made it possible to type those STR (D18, D21 and FGA) that showed locus dropout with SGM Plus. These alleles were confirmed by comparison with the DNA profiles of putative relatives. Further validation studies concerning DNA degradation are in progress and will be reported elsewhere.
      Figure thumbnail gr1
      Fig. 1Result of miniSTR amplification of 30 pg DNA with 34 cycles.

      Conflict of interest

      None.

      References

        • Coble M.D.
        • Butler J.M.
        Characterization of new miniSTR loci to aid analysis of degraded DNA.
        J. Forensic Sci. 2005; 50: 43-53
        • Grubweiser P.
        • et al.
        A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA.
        Int. J. Legal Med. 2006; 120: 115-120
        • Butler J.M.
        • Shen Y.
        • McCord B.R.
        The development of reduced size STR amplicons as tools for the analysis of degraded DNA.
        J. Forensic Sci. 2003; 48: 1054-1064
        • Gill P.
        • et al.
        The evolution of DNA databases—recommendations for new European STR loci.
        Forensic Sci. Int. 2006; 156: 242-244
        • Gill P.
        • et al.
        Letter to the Editor – New multiplexes for Europe – Amendments and clarification of strategic development.
        Forensic Sci. Int. 2006; 163: 155-157
        • Kimpton C.P.
        • et al.
        Automated DNA profiling employing multiplex amplification of short tandem repeat loci.
        PCR Meth. Appl. 1993; 3: 13-22
        • Decorte R.
        • et al.
        Allele frequency data for 19 short tandem repeats (PowerPlex® 16 and FFFl) in a Belgian population sample.
        J. Forensic Sci. 2006; 51: 436-437
        • Vanderheyden N.
        • et al.
        Identifcation and sequence analysis of discorcant phenotypes between AmpFlSTR SGM Plus™ and PowerPlex® 16.
        Int. J. Legal Med. 2007; 121: 297-301
        • De Maesschalck K.
        • et al.
        Y-chromosomal STR haplotypes in a Belgian population sample and identification of a micro-variant with a flanking site mutation at DYS19.
        Forensic Sci. Int. 2005; 152: 89-94