Validation of the AmpFℓSTR® SEfiler Plus™ PCR Amplification kit for forensic STR analysis

Received 1 September 2009 ,Accepted 1 September 2009.

  • Image Result

    Allele balances of heterozygous STR loci with the AmpFℓSTR® SEfiler Plus™ PCR Amplification kit. Results from 35 single-donar trace samples with 150–200pg DNA signals above 20 RFUs in positions of com

    Allele balances of heterozygous STR loci with the AmpFℓSTR® SEfiler Plus™ PCR Amplification kit. Results from 35 single-donar trace samples with 150–200pg DNA signals above 20 RFUs in positions of common alleles were included.

  • Image Result
    Allelic drop-outs with the AmpFℓSTR® SEfiler Plus™ PCR Amplification kit. Amplification of 50pg AmpFℓSTR® Control DNA 007 (AB). The expected alleles D21S11-28 and D18S51 (circles) were not detected.

    Allelic drop-outs with the AmpFℓSTR® SEfiler Plus™ PCR Amplification kit. Amplification of 50pg AmpFℓSTR® Control DNA 007 (AB). The expected alleles D21S11-28 and D18S51 (circles) were not detected.